Technical Parameters
Series | Test Items | Standard Requirements | Test Result | Test Method | |
1) | Slump | Vertical Placement(mm) | ≤3 | 0 | GB/T 13477 |
|
| Horizontal Placement | No deformation | No deformation | GB/T 13477 |
2) | Tack-free Time(h) | ≤3 | 0.3 | GB/T 13477 | |
3) | Extrudability(ml/min) | ≥150 | 1500 | GB/T 13477 | |
4) | Tensile Modulus ( 23℃)Mpa | ≤0.4 | 0.4 | GB/T 13477 | |
5) | Tensile Modulus ( -20℃)Mpa | ≤0.6 | 0.4 | GB/T 13477 | |
6) | Tensile Properties at Maintained Extension | No Breakage | No Breakage | GB/T 13477 | |
7) | Tensile Strength |
\ | 0.6 | GB/T 13477 | |
8) | Density(g/l) | \ | 1.02 | GB/T 13477 | |
9) | Hardness Shore A | \ | 18 | GB/T 13477 | |
10) | Elongation at break | \ | 300 | GB/T 13477 | |
Working Temperature
Adaptable temperature after curing: -40℃ to 150℃
Sealant Colour
Transparent colour or black colour
Usage Method
- The substrates and auxiliary materials used in the project must be tested for adhesion/compatibility.
- Air circulation must be maintained in the construction and curing environment;
- The substrate bonding surface must be clean, dry and free from dust, oil and water.
Restriction of Usage
- Not suitable for coated glass assembly
- Not suitable for stone, concrete, zinc iron and other materials surface
- Not suitable for use when the surface temperature of the substrate is lower than 6℃ or higher than 40℃.
*300ml/cartridge; 24 cartridges/ctn
*311ml/cartridge; 24 cartridges/ctn
12 months when stored in a cool, dry place below 27°C
A green environmental protection product,be compatible with GB14683-2017, FDA, CE and ROHS
- We supply integrateddata, technical consultation and free compatibility test.
- Solving problem in the course of using timely.
- Silicone sealants release volatile compounds during the curing process, which may be harmful to health ifinhaled for a long time, so good ventilation should be maintained in the construction site.
- The cured silicone sealant no longer releases harmful substances and will not have any harmful effects on the body.
- Keep uncured silicone sealants out of the reach of children. If they accidentally get into the eyes, please rinse with plenty of water and seek medical attention.
Interface Design & Construction Methods
Please refer to “GIRAFE Silicone Sealant Construction Guide”
Guarantee
- Our company has passed IS09001 and 15014001 management system certification, and strictly produces and controls product quality according to the requirements of 1S09001 quality system. In August 2006, it was approved as a certified enterprise for the production of silicone structural sealants for construction.
- After the user purchases the product and determines the construction unit and project, our company will issue a quality guarantee for silicone structural sealants.
Maintenance
- Generally no maintenance is required. If the silicone structural sealant seam is damaged, remove the ineffective silicone structural sealant, clean the substrate surface, and then fill it with silicone structural sealant.
- GIRAFE brand silicone structural sealant can adhere well to the cured silicone glue.