Technical Parameters
Series | Test Items | Standard Requirements | Test Method | |
1) | Slump | Vertical Placement(mm) | ≤3 | GB/T 13477 |
Horizontal Placement | No deformation | GB/T 13477 | ||
2) | Density (g/cm3) | 1.56±0.1 | GB/T 13477 | |
3) | Tack-free Time(min) | ≤50 | GB/T 13477 | |
4) | Tensile Strength (Mpa) | >1.3 | GB/T 528 | |
5) | Elongation at break(%) | >150 | GB/T 528 | |
6) | Hardness Shore A | 45±5 | GB/T 1741 | |
7) | volume resistivity (W.cm) | ≥1.5×10 14 | GB/T 1692 | |
8) | Dielectric Strength(KV/mm) | ≥20 | GB/T 1692 | |
Usage
- The best environmental conditions for the construction of the sealant are temperature 4 ℃ ~ 40 ℃, relative humidity of 40% ~ 80%.
- Clean the surface of adhered or coated objects before use, and use suitable solvents including anhydrous alcohol, isopropyl alcohol, acetone and so on.Remove rust, dust, oil and water.
- Cut the nozzle with a paper cutter, squeeze the adhesive onto the cleaned surface, make it evenly distributed, and close the sticky surface and fix it within the surface drying time.Put the coated parts in the air and let them cure at room temperature for 24 hours before putting them into use.
- After the operation is completed, the unused adhesive should be tightened the cap immediately, sealed and stored. When using again, if there is a little crust at the sealing place, it can be removed without affecting the normal use.
Storage
Keep in a cool and dry environment below 27℃, the shelf life of the product is 9 months after the date of production, the product can be handled and transported in accordance with the general chemical products.
The product can be handled and transported according to general chemicals.
Packing
300ml/cartridge, 24PCS/Carton; 590ml/sausage, 20PCS/Carton
Precautions
- Store away from children.
In case of inadvertent contact with skin, wipe clean and rinse with water immediately. In case of accidental contact with eyes, flush with water immediately and go to a hospital for examination.
It is recommended that the product be used in a well-ventilated area.
Users are advised to understand the product and its properties in detail and conduct compatibility tests before using the product. Due to the diversity of practical applications, we do not guarantee that the product will be used under certain conditions.
Due to the diversity of practical applications, our company does not guarantee any problems arising from the use of our products under certain conditions, and does not assume any responsibility for direct, indirect or accidental damages. Users
Users encounter any problems in the use of the process, you can maintain communication with our engineers, we will try our best to provide you with the best product application solutions.
Solutions.