Product

Insulating Glass Assembly Silicone Sealant In 2 Components

Product Features

  • Two-component, neutral room temperature curing, non-corrosive to glass, metal and other building materials, is designed for insulating glass assembly with silicone sealant.
  • Excellent weather resistance, the service life of more than 10 years under normal climatic conditions.
  • Under normal conditions without primer, it has good adhesion to most building materials.
  • Good compatibility with other neutral silicone sealants.

Main Application

  • Secondary bonding and sealing of non-structural insulating glass.

Technical Parameters

Series

Test Items

Standard Requirements

Test Result

Test Method

 1)

Slump

Vertical Placement(mm)

≤3

0

GB/T 13477

 

 

Horizontal Placement

No deformation

No deformation

GB/T 13477

2)

Pot Life(min)

≥30

50

GB/T 16776

3)

Tack-free Time(h)

≤2

1

GB/T 13477

Working Temperature

Adaptable temperature after curing: -40℃ to 150℃

Sealant Colour

Component A white colour; Component B black colour;Mixed colour black

Glazing Silicone Sealant

Usage Method

  • The base materials and auxiliary materials selected for the project must be tested for adhesion and compatibility, and can be put into use only after passing the test.
  • The design and construction of the project must strictly abide by the technical specifications stipulated by the state for relevant projects, and refer to the “GIRAFE Two Components Silicone Sealant For Insulating Glass Assembly Usage Guide”.
  • Air circulation should be maintained during construction and curing environments.
  • The bonding surface of the substrate must be cleaned with cleaning solvents such as toluene, xylene or acetone.
  • After the glue fills the joints, use a scraper to squeeze further inward to completely fill the joints with glue, and modify the glue surface before it solidifies.

Restriction of Usage

  • Cannot be used on all material surfaces that will exude grease, plasticizers or other organic solvents
  • Not suitable for use on frosted or dampsurfaces
  • Not suitable for use on places that are continuously soaked in water or humid all year round
  • Not suitable to work when the surface of the substrate is not clean or solid.
  • It is not suitable for construction when the surface temperature of the material is lower than 10°C or higher than 40°C
  • It should not be used at interfaces that bear structural strength on the ground or in areas subject to excessive physical damage.
  • Component A: 190L, Component B:19L
  • Component A: 19L, Component B:300ml*7

12 months when stored in a cool, dry place below 27°C

GB/T 29755-2013; Be compatible with FDA, CE and ROHS

  • We supply integrateddata, technical consultation and free compatibility test.
  • Solving problem in the course of using timely.
  • Silicone sealants release volatile compounds during the curing process, which may be harmful to health ifinhaled for a long time, so good ventilation should be maintained in the construction site.
  • The cured silicone sealant no longer releases harmful substances and will not have any harmful effects on the body.
  • Keep uncured silicone sealants out of the reach of children. If they accidentally get into the eyes, please rinse with plenty of water and seek medical attention.

Interface Design & Construction Methods

Please refer to “GIRAFE Silicone Structural Sealant Construction Guide”

Guarantee

  • Our company has passed IS09001 and 15014001 management system certification, and strictly produces and controls product quality according to the requirements of 1S09001 quality system. In August 2006, it was approved as a certified enterprise for the production of silicone structural sealants for construction.
  • After the user purchases the product and determines the construction unit and project, our company will issue a quality guarantee for silicone structural sealants.

Maintenance

  • Generally no maintenance is required. If the silicone structural sealant seam is damaged, remove the ineffective silicone structural sealant, clean the substrate surface, and then fill it with silicone structural sealant.
  • GIRAFE brand silicone structural sealant can adhere well to the cured silicone glue.

Estimated Amount of Use

Please see following form of estimated amount of various joints:

The length of GIRAFE Two Components Silicone Sealant For Insulating Glass Assembly ,take Component A 190L+ Component B 19L as an example

Spec.

Width

(6 mm)

Width

(9 mm)

Width

(12mm)

Width

(15mm)

Width

(18mm)

Width

(21mm)

Width

(24mm)

Thickness

(6mm)

Length

(5800m)

Length

(3870m)

Length

(2900m)

Length

(2261m)

Length

(1884m)

Length

(1615m)

Length

(1413m)

Thickness

(9mm)

 

Length

(2580m)

Length

(1935m)

Length

(1507m)

Length

(1256m)

Length

(1077m)

Length

(942m)

Thickness

(12mm)

 

 

Length

(1451m)

Length

(1131m)

Length

(942m)

Length

(808m)

Length

(706m)

  • Note: The actual amount of silicone sealant used will vary depending on the interface design, the installation location of the gasket material, the finishing technology, and the amount of loss on the construction site.
  • User Note: The information published in this article is what we believe to be reliable. Due to the wide variety of actual situations, we cannot understand all situations, so we cannot guarantee the correctness and applicability of our products in certain uses and purposes. Users should understand the product in detail before using it, and then decide the best way to use it.

Contact us

Wechat

Whatsapp

Contact Us